STORYLINE: A Notified Body performs MDR conformity assessment of an Artificial Intelligence software used in Emergency Departments to support Healthcare Professionals in triage activities. Patient/caregiver can enter data (anamnesis, patient history, vital signs) through an app or a kiosk rather than on a paper form and the software suggests priority levels to be validated by the hospital’s responsible healthcare professional.

PRIMARY PERSONA AND SUPPORTING PERSONAS WHERE RELEVANT: NB personnel involved in the conformity assessment, the technical, clinical, AI specialist reviewing the technical file and the auditor are usually experienced biomedical engineers, experienced in medical device and AI software development, looking at specific AI risks under MDR requirements. 

INFORMATION NEEDS: As part of the technical documentation, labelling and Instructions for Use, including

Identification details (in case of kiosk)
Download details (in case of mobile phone app)
Healthcare specialist handbook (for the software)
Patient handbook (for the kiosck or app)
eIFU & webpage (QR codes, links…).
Clinical evaluation report
Usability studies
Pre-clinical studies
Post Market Surveillance plan and report
UDI-DI
EUDAMED registration
Performance, Warnings from AI Software V&V and risk management

ROUTE(S) OF ACCESS TO INFORMATION: Today: Physical label and paper Instructions for use in the local language, including references to eIFU and webpage for software (for professional use) are usually provided to the Notified Body, together with the technical file, in pdf or electronic format, including eIFU and webpage link.

Target:

TRUSTWORTHINESS/QUALITY CONSIDERATIONS: The information on healthcare professional training (including AI software trustworthiness requirements), labelling and IFUs undergoing third party conformity assessment in EU is not always consistent throughout the technical documentation provided by the manufacturers. One source of truth (EUDAMED?), digitalization and international convergence are advisable. 

PRELIMINARY KPI CONSIDERATIONS: Indicators and software trustworthiness requirements are supposed to have been defined by the manufacturer in usability studies and reviewed by the relevant Notified Body and competent authorities (e.g. device identification, manufacturer identification, the presence of the CE mark with the Notified Body identification number, labelling border control).

If the AI software “keeps learning” from the hospital data, there are additional requirements on data governance, vigilance activities and performance monitoring (logging) throughout the whole software lifecycle to be monitored.

The AI related risks of over-trust, bias, accuracy drifts, also have to be monitored.