USE SCENARIO EXAMPLE: Assessment of digital labelling and electronic Instructions for Use (eIFU) for an IVD within TD assessment
STORYLINE: An IVD manufacturer provides device information through the physical product label together with digitally accessible information, including the Instructions for Use (IFU). As part of the conformity assessment, the Notified Body reviews the manufacturer’s technical documentation and the implementation of the digital information pathway. The assessment determines whether users can identify and access the applicable IFU, whether required information is provided, whether the information corresponds to the correct IVD and version, and whether previous IFU versions remain controlled and traceable. The assessment also considers cybersecurity, usability, risk management, post-market surveillance and change-management aspects associated with the digital information solution.
PRIMARY PERSONA AND SUPPORTING PERSONAS WHERE RELEVANT:
Primary persona: Notified Body product reviewer.
Supporting personas: Notified Body cybersecurity/software expert where applicable; manufacturer regulatory affairs representative; manufacturer quality representative; manufacturer IT/digital-labelling representative; risk-management and usability specialists
INFORMATION NEEDS: The assessor needs evidence demonstrating that the IVD’s physical and digital labelling system provides controlled, accurate, accessible and traceable information. Evidence reviewed includes: Label samples, IFU, Website/eIFU architecture, Cybersecurity documentation, Risk Management File, Usability Engineering File, PMS Plan and change management procedure
ROUTE(S) OF ACCESS TO INFORMATION:
Today: The Notified Body receives information mainly through the manufacturer’s technical documentation submission. The assessor may additionally follow the information pathway provided on the physical label, such as a URL, QR code or other digital access mechanism, to verify how an intended user obtains the IFU and related device information.
Target: A clearly structured and traceable digital information environment allowing the assessor to navigate from the IVD/device identifier to the applicable controlled IFU and, where necessary, its version history and related regulatory information.
TRUSTWORTHINESS/QUALITY CONSIDERATIONS: The Notified Body needs to establish that digitally provided information originates from the manufacturer, corresponds unambiguously to the relevant IVD, is complete and current, and is protected against uncontrolled modification. Document/version control should enable traceability between the device, applicable IFU revision and previous versions. Changes affecting digital labelling should be integrated into the manufacturer’s change-management, risk-management and PMS processes. Accessibility and usability should reduce the risk that an intended user retrieves an incorrect or obsolete IFU.
PRELIMINARY KPI CONSIDERATIONS:
Time required by the assessor/user to locate the correct IFU and labels
Percentage of tested IVDs for which the correct IFU and Lables can be retrieved without ambiguity
Traceability between label, device identifier and IFU revision
Number of labelling/eIFU-related assessment findings
Number of PMS complaints associated with unavailable, incorrect or outdated digital information